Overview: Box substation, also known as pre-installed substation or pre-installed substation. Is a kind of high voltage switch equipment, distribution transformers and low voltage power distribution equipment, according to the wiring scheme must be arranged in one of the factory power...
Sende bookingforespørsel
produkt introduksjon

Box substation, also known as pre-installed substation or pre-installed substation. Is a kind of high voltage switch equipment, distribution transformers and low voltage power distribution equipment, according to the wiring scheme must be arranged in one of the factory power distribution equipment, indoor, outdoor compact type is, step-down transformer, low voltage power distribution and other functions organically combined together, installed in a moisture, rust, dust, rat, fire prevention, guard against theft, thermal insulation, fully enclosed, movable steel structure, especially suitable for city network construction and retrofit, is after ten built substations rise a new substation.


Pre-installed substation (station) :

Pre-installed and type tested complete set of equipment, usually composed of high-voltage distribution device, transformer, low-voltage distribution device, and combined in one or more boxes. Also referred to as "box change".


The enclosure of box-type substation is made of steel plate or alloy plate, equipped with double top cover, with good heat insulation. The shell and skeleton are all treated with antisepsis and have the condition of long-term outdoor use. Shape and color can be in harmony with the environment. It is easy to install. There is a cable room under the foundation of the box substation, and a manhole in the low-voltage room can enter the cable room for work. From the point of view of volume, the European box transformer due to the internal installation of conventional switchgear and transformer, the product volume is larger. The American type box transformer is smaller in size due to its integrated installation.

box substations

The high voltage side of the box is protected by load switch and current limiting fuse. When a phase fuse is blown out, the hammer of the fuse is used to make the load switch three identical time slots, so as to avoid the phase-missing operation. The load switch is required to have the ability to cut off the transfer current. The low-voltage side is protected by a load switch with a current-limiting fuse, and the high-voltage side of the American box transformer is protected by a fuse, while the load switch only switches on and off the function of high-voltage load current, with a small capacity. When a phase fuse fuses on the high voltage side, the voltage on the low voltage side will be lowered, and the plastic case automatic air switch will operate under voltage protection or over current protection, and the low voltage operation will not occur. Look from product cost, Europe type box becomes this tall. From the point of view of product price reduction space, there is still a large space for price reduction of American box transformer. On the one hand, the three-phase five-column core of American box transformer can be changed to three-phase three-column core.